CPSC Warns Public Of Fire/Explosion Hazard Associated With Suspect Gas Leak Detector Fluid

Name of Product:
Gas Leak Detector Fluid
Hazard:

A blue colored gas leak detector fluid can corrode brass fittings and lead to hazardous gas leaks and subsequent fires and explosions.

Remedy:
Inspect
Repair
Recall Date:
January 06, 1975
Units:

 1,155 gallons of the solution, in various package sizes, to 117 gas companies.

Recall Details

Description:

Washington, D.C. --The U.S. Consumer Product Safety Commission today warned consumers, mobile home manufacturers and distributors, and gas companies in Minnesota, Wisconsin, Iowa, Nebraska, North and South Dakota that a blue colored gas leak detector fluid distributed since 1972 by L.P. Gas Equipment, Inc., St. Paul, Minnesota, can corrode brass fittings and lead to hazardous gas leaks and subsequent fires and explosions.

Any person or company that has used this detector fluid on brass connectors should have the piping inspected immediately for corrosion or discoloration. The connectors should be replaced as quickly as possible.

Consumers in these states who have had gas appliances installed or inspected for leaks since 1972 should contact the company that installed the product or their local gas company for an immediate inspection.

The corrosion problem apparently is due to the presence of ammonia in the fluid.

A common method of installing gas appliances is to use a flexible brass connector to connect the appliance to rigid piping. If a leak detector fluid containing ammonia is used to check for faulty tube fittings, the ammonia residue can cause cracks and leaks in the brass. These cracks can enlarge over time.

The fluid was manufactured by Fremont Industries, Shakopee, Minnesota, for L. P. Gas Equipment, Inc., which sold 1,155 gallons of the solution, in various package sizes, to 117 gas companies.

L. P. Gas has asked its purchasers-- none of whom would be consumers -- to discontinue use of the fluid and to destroy existing stocks.

The Commission obtained the names of these customers by subpoena and is advising them of the serious nature of the hazard. The Commission also is encouraging immediate inspection and replacement of all fittings that may have been treated with the suspect leak detector fluid.

At the same time, the Commission is proceeding with administrative action that could lead to mandatory corrective action by the manufacturer, distributors and retailers of the fluid.

The State of Minnesota, Building Code Division, reported the potential problem of the ammonia containing fluid to the Commission's Minneapolis Area Office in September 1974. The Commission consulted with the National Bureau of Standards in order to confirm that the corrosion damage was, or could have been, caused by the ammonia solution.

 

Remedy:

Any person or company that has used this detector fluid on brass connectors should have the piping inspected immediately for corrosion or discoloration. The connectors should be replaced as quickly as possible.

Distributor(s):
L.P. Gas Equipment, Inc., St. Paul, Minnesota
Recall number:
75-005

请注意:各位委员会委员对相关题目可能会发表声明。请访问www.cpsc.gov/commissioners搜寻这一或其它题目的相关声明。

If you are experiencing issues with a recall remedy or believe a company is being non-responsive to your remedy request, please use this form and explain the situation to CPSC.
About the U.S. CPSC

The U.S. Consumer Product Safety Commission (CPSC) is charged with protecting the public from unreasonable risk of injury or death associated with the use of thousands of types of consumer products. Deaths, injuries, and property damage from consumer product-related incidents cost the nation more than $1 trillion annually. CPSC's work to ensure the safety of consumer products has contributed to a decline in the rate of injuries associated with consumer products over the past 50 years.

Federal law prohibits any person from selling products subject to a Commission ordered recall or a voluntary recall undertaken in consultation with the CPSC.

For lifesaving information:
Choose Your Recall Emails Get Notified About Each Recall via Email.
Report an unsafe product