Royal Sovereign Corp., a corporation, Provisional Acceptance of a
Settlement Agreement and Order
[Federal Register: August 15, 2000 (Volume 65, Number 158)]
[Notices]
[Page 49789-49791]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr15au00-34]
-----------------------------------------------------------------------
CONSUMER PRODUCT SAFETY COMMISSION
[CPSC Docket No. 00-C0011]
Royal Sovereign Corp., a corporation, Provisional Acceptance of a
Settlement Agreement and Order
AGENCY: Consumer Produce Safety Commission.
ACTION: Notice.
-----------------------------------------------------------------------
SUMMARY: A Settlement Agreement provisionally accepted by the Consumer
Produce Safety Commission was inadvertently published on August 9, 2000
(pages 48680-48682) separate from a preamble notice about the agreement
published on August 8, 2000 (page 48488). This notice accurately
publishes the Settlement Agreement and preamble together and sets the
period for comment on the agreement.
It is the policy of the Commission to publish settlements which it
provisionally accepts under the Federal Hazardous Substances Act in the
Federal Register in accordance with the terms of 16 CFR 1118.20(e).
Published below is a provisionally-accepted Settlement Agreement with
Royal Sovereign Corp., a corporation, containing a civil penalty of
$20,000.
DATES: Any interested person may ask the Commission not to accept this
agreement or otherwise comment on its contents by filing a written
request with the Office of the Secretary by August 30, 2000.
ADDRESSES: Persons wishing to comment on this Settlement Agreement
should send written comments to the Comment 00-C0011, Office of the
Secretary, Consumer Product Safety Commission, Washington, DC 20207.
FOR FURTHER INFORMATION CONTACT: Margaret H. Plank, Trial Attorney,
Office of Compliance and Enforcement, Consumer Product Safety
Commission, Washington, DC 20207; telephone (301) 504-0626, 1450.
SUPPLEMENTARY INFORMATION: The text of the Agreement and Order appears
below.
Dated: August 10, 2000.
Sadye E. Dunn,
Secretary.
Settlement Agreement and Order
1. This Settlement Agreement and Order between Royal Sovereign
Corporation (``Royal Sovereign''), a New Jersey corporation, and the
staff of the United States Consumer Product Safety Commission (``the
CPSC''), pursuant to 16 CFR 1118.20 of the Commission's Procedures for
Investigations, Inspections, and Inquiries under the Consumer Product
Safety Act (``CPSA''), reflects a compromise resolution of the matter
described herein, entered without a hearing or determination of issues
of law and fact.
I. The Parties
2. The staff is the staff of the United States Consumer Product
Safety Commission, an independent federal regulatory agency responsible
for the enforcement of the Consumer Product Safety Act, 15 U.S.C. 2051-
2084.
3. Royal Sovereign is a corporation organized and existing under
the laws of the State of New Jersey. Its principal corporate offices
are located at 100 West Sheffield Ave., Englewood, NJ 07631. Royal
Sovereign is an importer and distributor of small electronic
appliances, including portable ceramic heaters.
II. Staff Allegations
4. Section 15(b) of the CPSA, 15 U.S.C. 2064(b) requires a
manufacturer of a consumer product who, inter alia, obtains information
that reasonably supports the conclusion that the product contains a
defect which could create a substantial product hazard or creates an
unreasonable risk of serious injury or death, to immediately inform the
Commission of the defect or risk.
5. Between 1992 and 1996, Royal Sovereign imported and distributed
within the United States approximately 39,300 model RST1200 oscillating
ceramic portable heaters (``RST 1200 heaters''). The portable heaters
are ``consumer products'' and Royal Sovereign is a ``distributor'' of
``consumer products'' that are ``distributed in commerce'' as those
terms are defined in sections 3(a)(1), (4), (11) of the CPSA, 15 U.S.C.
2052(a)(1), (4), (11).
6. The RST 1200 heaters are defective because the mechanism that
rotates the heater side-to-side can wear through the insulation of
electrical wiring inside the heater's base. In addition, some of the
connections between the electrical wires and other components inside
the heater are faulty. Either of these conditions can cause a fire.
7. Between 1994 and 1997, Royal Sovereign received at least
thirteen reports of fires involving RST 1200 heaters. The fires
resulted in property damage claims in excess of $70,000.
8. On October 24, 1995, CPSC field investigator William Robinson
inspected the facilities of Royal Sovereign, and interviewed firm
officials, seeking information about a fire involving an RST 1200
heater that had been reported to the Commission by the consumer. Mr.
Robinson shared the staff's engineering evaluation of the unit involved
in the fire, which concluded that faulty crimp connections may have led
to arcing and overheating within the unit that caused ignition of the
plastic housing. Firm officials informed Mr. Robinson at that time that
they believed the RST 1200 heater involved in the fire had been
tampered with, and that the faulty crimps were not of Royal Sovereign's
manufacture.
9. Royal Sovereign also informed Mr. Robinson on October 24, 1995,
that Royal Sovereign had received reports of two additional fires
involving RST 1200 heaters. Firm officials states that one of those
fires resulted from the heater being placed too close to combustibles,
and that they believed the other fire had been deliberately set. Mr.
Robinson was told that the other complaints the firm had received
concerning the RST 1200 related to mechanical failures or product
dissatisfaction.
10. At the conclusion of his inspection, Mr. Robinson left with
Royal Sovereign copies of the CPSC statutes and regulations setting
forth a distributor's obligations to report potential safety hazards to
the Commission.
11. In 1996, Royal Sovereign undertook an ``upgrade'' program,
pursuant to which it contacted those consumers of RST 1200 heaters from
whom the firm had received warranty cards and informed them that they
could return their heaters for ``reconfiguration to 1996 standards.''
[[Page 49790]]
The ``upgrade'' involved opening the units to evaluate the crimp
connections and the installation of a sleeve over the power cord, which
entered the unit in such a way as to rub up against an internal metal
disc that provided the oscillating motion for the unit. The addition of
the protective sleeve guarded against abrasion of the cord. Abrasion of
the cord could result in the exposure of current-carrying wires, which,
in turn, could result in arcing and fire. Royal Sovereign did not
notify the staff of its upgrade program.
12. Between October 1995 and April 1997, Royal Sovereign became
aware of ten additional fires involving RST 1200 heaters.
13. Royal Sovereign did not report the additional incidents of fire
involving RST 1200 heaters to the Commission.
14. In October 1997, the staff executed an administrative search
warrant on the facilities of Royal Sovereign and recovered several
burned units of RST 1200 heaters, as well as a number of additional
returned units exhibiting indicia of fire. The staff also collected new
samples of RST 1200 heaters for evaluation. In addition, the staff
collected documentation of fire incidents involving RST 1200 heaters,
including insurance claim documentation, internal tracking records, and
correspondence with consumers. Finally, the staff collected over 100
consumer complaints noting incidents of sparking, smoking, or flaming
RST 1200 heaters.
15. The staff's evaluation of the returned units, as well as the
new samples, indicated that the units utilized crimp connections
similar to those identified as potentially hazardous by the staff in
1995. The staff also noted evidence of abrasion of the power cords in
the burned units.
16. Although Royal Sovereign had obtained sufficient information to
reasonably support the conclusion that the RST 1200 heaters contained a
defect which could create a substantial product hazard, or created an
unreasonable risk of serious injury of death, it failed to report such
information to the Commission, as required by section 15(b) of the
CPSA. This is a violation of section 19(a)(4) of the CPSA, 15 U.S.C.
2068(a)(4).
17. Royal Sovereign's failure to report to the Commission, as
required by section 15(b) of the CSA, was committed ``knowingly,'' as
that term is defined in section 20(d) of the CPSA, and Respondent is
subject to civil penalties under section 20 of the CPSA.
III. Response of Royal Sovereign
18. Royal Sovereign denies it violated the CPSA. Royal Sovereign
also denies that the RST 1200 heaters contain a defect which could
create a substantial product hazard, or create an unreasonable risk of
injury or death. Royal Sovereign also denies that the RST 1200 heaters
caused any of the fires referred to in this document, or could cause a
fire. Royal Sovereign also denies that it violated the reporting
requirements of the CPSA.
IV. Agreement of the Parties
19. The Commission has jurisdiction over this matter under the
CPSA, 15 U.S.C. 2051-2084.
20. Royal Sovereign agrees to pay to the Commission a civil penalty
in the amount of $20,000, to be paid in four equal installments of
$5000. The first payment shall become due immediately upon the CPSC's
final acceptance of the attached Order. Subsequent payments shall be
made thirty (30), sixty (60), and ninety (90) days after that date.
21. Respondent knowingly, voluntarily and completely waives any
rights it may have (1) to an administrative or judicial hearing, (2) to
judicial review or other challenge or contest of the validity of the
commission's Order, (3) to a determination by the Commission as to
whether Respondent failed to comply with section 15(b) of the CPSA, as
alleged, (4) to a statement of findings of fact and conclusions of law,
and (5) to any claims under the Equal Access to Justice Act.
22. This Settlement Agreement and Order shall not be deemed or
construed as an admission of liability or wrongdoing by Royal Sovereign
or as evidence: (a) of any violation of law or regulation by Royal
Sovereign; (b) of other wrongdoing by Royal Sovereign; (c) that RST
1200 heaters are defective, create a substantial product hazard, or are
unreasonably dangerous; or (d) of the truth of any claims or other
matters alleged or otherwise stated by the CPSC or any other person
either against Royal Sovereign or with respect to RST 1200 heaters.
23. Upon provisional acceptance of this Settlement Agreement and
Order by the Commission, this Settlement Agreement and Order shall be
placed on the public record and shall be published in the Federal
Register in accordance with the procedures set forth in 16 CFR
1118.20(e). If the Commission does not receive any written request not
to accept the Settlement Agreement and Order within 15 days, the
Settlement Agreement and Order shall be deemed finally accepted on the
16th day after the date it is published in the Federal Register, in
accordance with 16 CFR 1118.20(f).
24. This Settlement Agreement and Order becomes effective upon its
final acceptance by the Commission and service upon Respondent.
25. The Commission may publicize the terms of the Settlement
Agreement and Order.
26. The provisions of this Settlement Agreement and Order shall
apply to Respondent, its successors and assigns, agents,
representatives, and employees, directly or through any corporation,
subsidiary, division, or other business entity, or through any agency,
device or instrumentality.
27. Royal Sovereign agrees to immediately inform the Commission if
it learns of any additional incidents involving the RST 1200 heaters,
or any additional information regarding the alleged defect and hazard
identified in paragraph six, herein.
28. Nothing in this Settlement Agreement and Order shall be
construed to preclude the Commission from taking such other and further
actions as the Commission deems necessary to protect the public health
and safety and to comply with the CPSA.
29. This Settlement Agreement may be used in interpreting the
Order. Agreements, understandings, representations, or interpretations
made outside of this Settlement Agreement and Order may not be used to
vary or contradict its terms.
Dated: May 16, 2000.
Ta K. Lim,
Royal Sovereign Corporation.
Dated: May 10, 2000.
Alan Schoem,
Assistant Executive Director, Office of Compliance.
Eric Stone, Director,
Legal Division, Office of Compliance.
Margaret H. Plank,
Attorney, Legal Division, Office of Compliance.
Order
Upon consideration of the Settlement Agreement entered into between
Royal Sovereign Corporation, a corporation, and the staff of the U.S.
Consumer Product Safety Commission; and the Commission having
jurisdiction over the subject matter and Royal Sovereign Corporation,
and it appearing that the Settlement Agreement and Order is in the
public interest, it is
Ordered, that the Settlement Agreement be and hereby is accepted,
and it is
Further Ordered, Royal Sovereign Corporation shall pay the
Commission a civil penalty in the amount of TWENTY
[[Page 49791]]
THOUSAND AND 00/100 dollars ($20,000). The penalty shall be paid in
four equal installments of FIVE THOUSAND AND 00/100 dollars ($5,000).
The first payment shall be due within ten (10) days after service of
this Final Order upon Royal Sovereign Corporation. Subsequent payments
shall be due thirty (30), sixty (60), and ninety (90) days thereafter.
In the event that Royal Sovereign Corporation fails to make a
payment in accordance with the terms of this Order, or makes a payment
that is at least days late, the outstanding balance of the civil
penalty shall become due and payable within five days, and the interest
on the outstanding balance shall accrue and be paid at the federal
legal rate of interest under the provisions of 28 U.S.C. 1961(a) and
(b).
Provisionally accepted and Provisional Order issued on the 3rd day
of August, 2000.
By Order of the Commission.
Sadye E. Dunn,
Secretary, Consumer Product Safety Commission.
[FR Doc. 00-20735 Filed 8-14-00; 8:45 am]